• MDR-20
  • MDR-20

MDR-20

Description:

MDR-20 is a slim line DIN rail Class I switching power supply.Designed with a fully isolated plastic case to prevent user contact and the risk of shock.Featuring up to 88% efficiency this series can be cooled using only free air convection up to 60°C which significantly increases the reliability and lifetime of the power supply.Other standard features include its low no-load power consumption, to save energy, short circuit, overload, and over voltage protections, and DC OK relay contact with LED indicator for monitoring the PSU status.

Inquiry >

  • Type and Specification

     
     
MODEL     
     
     

MDR-20-5MDR-20-12MDR-20-15MDR-20-24

DC   VOLTAGE5V12V15V24V

RATED   CURRENT3A1.67A1.34A1A

CURRENT   RANGE0   ~ 3A0   ~ 1.67A0   ~ 1.34A0   ~ 1A

RATED   POWER15W20W20W24W

RIPPLE   & NOISE (max.) Note.280mVp-p120mVp-p120mVp-p150mVp-p
OUTPUTVOLTAGE   ADJ. RANGE4.75   ~ 5.5V10.8   ~ 13.2V13.5   ~ 16.5V21.6   ~ 26.4V

VOLTAGE   TOLERANCE Note.3±2.0%±1.0%±   1.0%±   1.0%

LINE   REGULATION±1.0%±1.0%±1.0%±1.0%

LOAD   REGULATION±1.0%±1.0%±   1.0%±   1.0%

SETUP,   RISE TIME Note.5500ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load

HOLD   UPTIME (Typ.)50ms/230VAC 20ms/115VAC at full load

VOLTAGE   RANGE85 ~ 264VAC 120 ~ 370VDC

FREQUENCY   RANGE47 ~63Hz
INPUTEFFICIENCY   (Typ.)76%80%81%84%

AC   CURRENT (Typ.)0.55A/115VAC 0.35A/230VAC

INRUSH   CURRENT (Typ.)COLD START 20A/115VAC,40A/230VAC

LEAKAGE   CURRENT<1mA/240VAC

OVERLOAD105 ~ 160% rated output power
PROTECTIONProtection type: Constant current limiting, recovers automatically after fault condition is removed

OVER VOLTAGE5.75   ~ 6.75V13.8   ~ 16.2V17.25   ~ 20.25V27.6   ~ 32.4V

Protection type: Shut down o/p voltage, re-power on to recover
FUNCTIONDC   OK ACTIVE SIGNAL (max.)3.75   ~ 6V / 50mA9   ~ 13.5V / 40mA11.5   ~ 16.5V / 40mA18   ~ 27V / 20mA

WORKING   TEMP.-20 ~ +70C (Refer to “Derating   Curve”)

WORKING   HUMIDITY20 ~ 90% RH non-condensing
ENVIRONMENTSTORAGE   TEMP., HUMIDITY-40 ~ +85C, 10 ~ 95% RH

TEMP.   COEFFICIENT±0.03%/C (0 ~ 50C)

VIBRATIONComponent: 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6

SAFETY   STANDARDSUL508, TUV EN60950-1 approved
SAFETY   &WITHSTAND   VOLTAGEI/P-O/P: 3KVAC I/P-FG: 2KVAC O/P-FG: 0.5KVAC
EMCISOLATION   RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC /   25C/ 70% RH

EMC   EMISSIONCompliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3

EMC   IMMUNITYCompliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-1, EN61204-3, light industry level, criteria A

MTBF236.9K hrs min. MIL-HDBK-217F (25C)
OTHERSDIMENSION22.5*90*100mm (W*H*D)

PACKING0.19Kg; 72pcs/14.7Kg/0.91CUFT
NOTE1.All parameters NOT specially mentioned are   measured at 230VAC input, rated load and 25°C of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor.
3.Tolerance : includes set up   tolerance, line regulation and load regulation.
4.The power supply is considered   a component which will be installed into a final equipment. The final   equipment must be re-confirmed that it still meets EMC directives.
5.Length of set up time is   measured at cold first start. Turning ON/OFF the power supply may lead to   increase of the set up time.