Description:
NDR-240 is a slim line DIN rail Class I switching power supply.Designed with a fully isolated plastic case to prevent user contact and the risk of shock.Featuring up to 88% efficiency this series can be cooled using only free air convection up to 60°C which significantly increases the reliability and lifetime of the power supply.Other standard features include its low no-load power consumption, to save energy, short circuit, overload, and over voltage protections, and DC OK relay contact with LED indicator for monitoring the PSU status.
Model / Specification | NDR-240-24 | NDR-240-48 |
DC Output Voltage | 24V | 48V |
Rated Output Current | 10A | 5A |
Output Current Rage | 0-10A | 0-5A |
Wave And Noise (Note3) | 150mVp-p | 150mVp-p |
Inlet Stability (Note4) | ±0.5% | ±0.5% |
Load Stability (Note5) | ±1% | ±0.5% |
DC Output Power | 240W | 240W |
Efficiency | 88% | 85% |
Adjustable Range For DC Voltage | 21.6-26.4V | 43.2-52.8V |
AC Input Voltage Range | 88~264VAC 47~63HZ;120~370VDC | |
Input Current | 3.5A/115V | |
1.8A/230V | ||
AC Impulse Current | Cold-start current: | |
30A/115V | ||
50A/230V | ||
Overload Protection | 105%~150% Type: Pulsing hiccup shutdown Reset: auto-recovery | |
High-Temperature Protection | 100°C±5°C (TSW1) | |
Setup Rise Hold-Up Time | 1500ms,100ms/230VAC | |
Withstand Voltage | Input and output interval: 3KVAC, | |
Input and enclosure: 1.5KVAC, | ||
Output and enclosure: 0.5KVAC | ||
Isolation Resistance | Input and output interval, Input and enclosure, Output and enclosure: 500VAC/100M Ohms | |
Working Temperature And Humidity | -10°C ~ +50°C, 20%~90%RH | |
Store Temperature And Humidity | -20°C ~ +85°C, 10%~95RH | |
Overall Dimension | 125.2*125.2*100mm | |
Weight | 1.2Kgs 20PCS/14.4KG/1.2CUFT | |
Safety Standards | CE |