• PSC-250
  • PSC-250

PSC-250

Description:

The PSC-250W provides 250W of backup-ready power with 12V/14.5A or 24V/10A outputs. It features adjustable voltage (11.3–14.9V for 12V models) and 89% efficiency. Designed for high-demand environments, it offers overload protection, low-battery cutoff, and seamless AC/battery. The 215×115×30mm chassis (0.75kg) includes LED indicators and operates in -20°C to +60°C. Suitable for servers, industrial controllers, and LED signage, its universal input (90–264VAC) and 1.5kV isolation ensure reliability in commercial and harsh settings.

Inquiry >

  • Type and Specification
  ModelPSC-250-12PSC-250-24
  DC Output VoltageCH1:13.8VCH2:13.8VCH1:27.6VCH2:27.6V
  Output Voltage Tolerance±1%—–±1%—–
  Rated Output Current14.5A3.5A(charge)6.5A2.5A(charge)
  Output Current Range0~18A—–0~9A—–
  Output Power250W250W
  Ripple and Noise180mVp-P—–200mVp-P—–
  Adjustable Range of DC VoltageCH1:11.3~14.9V  CH1:21.3~29.8V
  Start-up,Rise,and Hold Time600ms,50ms,80ms/230VAC.1200ms.50ms.16ms/115VAC.
  Input Voltage Range90~264VACor 135~370VDC
  ACInput Current4.5A/115VAC 2.5A/230VAC
  Efficiency87%89%
  Inrush CurrentCold Start Current 45A/115VAC           55A/230VAC
  Leakage Current<lmA/240VAC
  Overload ProtectionOverload protection will be activated at 105%to 115%of the rated output power.

Protetion mode:ACcharging mode:Isolation mode,the system can automaticall resume operation after the abnormalload condition is removed.
  Low Battery Voltage Protection9.5~10.3V19~20.5V

Protection mode:Output cut-off.
  Introduction to UPS FunctionLong-term online float charging for batteries with high efficiency,over 98%fullness

Automatically stops charging when full to prevent overcharge and extend battery ite.

Automatic switch between utility power and battery without delay,nomanual operation needed

Cold start capability allows UPSto start directly from battery in case of no utility power,meeting emergency needs
  Operating Temperature and Humidity-20°Cto~60°C;20%~90%RH(Please refer to theload derating curve)
  Storage Temperature and Humidity-20℃~+85C;10%~95%RHNon-condensing
  Shock Resistance10~500Hz,2G 10min./per cycle,duration 60 minutes,on each axis
  Voltage Withstanding CapabilityBetween input and output:1.5kVAC Between input and ground:1.5kVAC Between output and ground:0.5kVDC
  Insulation ResistancBetween input and output,input and ground,output and ground:100MQ/500VDC
  Dimensions215*115*30mm(L*W*H)
  Packaging0.75kg/20pcs/18.5kg/0.041m³


Get a quote

PSC-250

Prev:PSC-150

Next:PSC-350

Contact Us
We will answer you 24 hours a day
+86 15858810718