Description:
DR-120 series is a single output Din rail type power supply that can be installed on TS-35/7.5 or 15 DIN rails.Adopting the full range 86-264VAC input, the entire series provides an output voltage line of 5V,12V,15V,24V,36V and 48VDR-120 is a reliable switching power supply with high-quality material, durable, and safety to use.
Model | DR-120-12 | DR-120-15 | DR-120-24 | DR-120-48 |
DC Output Voltage | 12V | 15V | 24V | 48V |
Output Voltage Range | ±2% | ±2% | ±1% | ±1% |
Rated Output Current | 10A | 8A | 5A | 2.5A |
Output Current Range | 0-10A | 0-8A | 0-5A | 0-2.5A |
Wave And Noise | 85mVp-p | 85mVp-p | 85mVp-p | 100mVp-p |
Inlet Stability | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load Stability | ±1% | ±1% | ±1% | ±1% |
DC Output Power | 120W | 120W | 120W | 120W |
Efficiency | 80% | 81% | 84% | 85% |
Adjustable Range For DC Voltage | 10.8~13.2V | 13.5~16.5V | 21.6~26.4V% | 43.2~52.8V% |
AC Input Voltage Range | 88~132VAC 47~63Hz; 240~370VDC | |||
Input Current | 3.3A/115V 2A/230V | |||
AC Inrush Current | Cold-start current 30A/115V 60A/230V | |||
Leakage Current | <3.5mA/240VAC | |||
Overload Protection | 105%~150% Type: pulsing hiccup shutdown Reset: tuto recovery | |||
Over-Voltage Protection | 13.8~16.2V | 18~21V | 27.6~32.4V | 58~62V |
Temperature Coefficient | ±0.03%/°c(0~50°c) | |||
Setup, Rise , Hold Up Time | 500ms, 70ms, 50ms/230V | |||
Vibration | 10~500Hz, 2G 10min, /1cycle, Period for 60min, Each axes | |||
Withstand Voltage | Input and output internal: Input and encolsur: 1.5KvAC, Output and enclosure: 0.5KvAC | |||
Isolation Resistance | Input and output internal: Input and enclosure, Output and enclosure: 500VDC/100MΩ | |||
Working Temperature And Humidity | 10°c~50°c(Refer to output derating curve), 20%~90%RH | |||
Overall Dimension | 65.5×125.2×100mm | |||
Weight | 0.8Kgs 24PCS/19.2Kg/1.1CUFT | |||
Safety Standards | Meet UL 1012 requiement (Not apply for the mark) | |||
EMC Standards | Meet FCC PART 15 J Conduction class B |