• S-2400
  • S-2400

S-2400

Description:

2400W Switching CNC Power Supply can be widely used in Industrial Automation and CNC Stepper/Servo Systems.
115/230V AC range selectable, air cooling by the built-in fan.
Filter capacitance; High withstand voltage; Low dissipation; Large capacity.
Widely being used in Industrial automation, LED display, electronic equipment, communications, etc.

Inquiry >

  • Type and Specification
ModelS-2400-24S-2400-27S-2400-36S-2400-48
OutputDC Output Voltage24V27V36V48V
Output Voltage Tolerance±1%±1%±1%±1%
Rated Output Current100A89A67A50A
Output Current Range0-100A0-89A0-67A0-50A
Output Power2400W2400W2400W2400W
Ripple And The Noise240mVp-p240mVp240mVp-p480mVp-p
DC Voltage Adjustable Scope+5%; By external 2~ 5V voltage control, which can adjust the output voltage of the rated voltage the in the range of 40% ~ 100% in value
Start, Rise, Keep Time800ms, 50ms, 16ms Loaded with
InputInput Voltage Range200V~264VAC 47~63 Hz; 290~370VDC
Exchange Input Current11A/ 230 VAC
Efficiency85%85%86%87%
120A/230V
Leakage Current3.5 mA/240VAC
Protection CharacteristicsOverload Protection110%~135%
Protection way: current limiting, delay shut off, restart
High-Temperature ProtectionTSW1 (power tube) temperature > 100 ℃, restart when cut off output
EnvironmentWorking Temperature, Humidity-10℃ ~ +65℃, 20%~90 %RH
Keep Temperature, Humidity-20℃ ~ +85℃, 10%~95 %RH
Vibrate Resistance10~200Hz AC, 2G 10min. / 1 cycle time, 60 minutes, the axis
SecurityCompression SexI/P-O/P, I/P-FG: 1500VAC
Insulation ResistanceI/P-O/P, I/P-FG, >100M Ohms / 500VDC
EMC StandardAccord with
FCC Part 15 Class A
OtherWeight5.3Kg;
Packaging2pcs/11kg/CARTON
note1. All the parameters in have not been specified, all are in 230 VAC voltage input, rated load, and 25 ℃ conditions measuring income value.
2. Ripple and noise voltage are in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement.
3. Tolerance is voltage setting error, the voltage adjustment rate, and adjusting the sum total of the current rate.
4. The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index.


Get a quote