Description:
SE-1000 is a 1KW single output enclosure AC to DC / DC to DC power supply.
The entire series has an input voltage range of 180 – 264VAC / 250 – 370VDC and can provide DC output to meet most industrial needs.
Each model can be cooled by an internal speed-controlled fan and the operating temperature can reach 60℃.
Built-in adjustable output voltage and current, remote on/off control, auxiliary power supply and other features provide a variety of design flexibility
Model | SE-1000-12 | SE-1000-24 | SE-1000-36 | SE-1000-48 | SE-1000-72 | SE-1000-96 | SE-1000-110 | SE-1000-150 | SE-1000-220 | |
Output Characteristics | DC output voltage | 12V | 24V | 36V | 48V | 72V | 96V | 110V | 150V | 220V |
Rated current | 83.3A | 41.7A | 27.8A | 20.8A | 13.9A | 10.4A | 9.1A | 6.7A | 4.5A | |
Current range | 0-83.3A | 0-41.7A | 0-27.8A | 0-20.8 | 0-13.9A | 0-10.4A | 0-9.1A | 0-6.7A | 0-4.5A | |
Rated Power | 1000W | |||||||||
Ripple | 200mV | 200mV | 260mV | 350mV | 500mV | 600mV | 850mV | 900mV | 1000mV | |
Constant current optimum range | 6-12V | 12-24V | 18-36V | 24 -48V | 36-72V | 48-96V | 55-110V | 75 -150V | 110-220V | |
Voltage accuracy | ±1.0% | |||||||||
Line Regulation | ±1.0% | |||||||||
Load Regulation | ±1.0% | |||||||||
Startup & Rise Time | 1500mS,100mS/230VAC(Fully loaded) | |||||||||
Voltage range | 180-264VAC/245-370VDC | |||||||||
Input characteristics | Frequency range | 45Hz -65Hz | ||||||||
Power Factor | PF≥0.65/230VAC(Fully loaded) | |||||||||
efficiency | 85% | 86% | 87% | 89% | 90% | 90% | 90% | 91% | 91% | |
AC Current | <11A | |||||||||
Leakage Current | <3.0mA/240VAC | |||||||||
Short Circuit | Enter constant current | |||||||||
Over temperature | Shut down the output, and automatically recover or restart after the temperature drops | |||||||||
Protection features | Output voltage adjustment | 0-13.2V | 0-26.4V | 0-39.6V | 0-52.8V | 0-79.2V | 0-105.6V | 0-121V | 0-165V | 0-242V |
Output constant current adjustment | 0-83.3A | 0-41.7A | 0-27.8A | 0-20.8A | 0-13.9A | 0-10.4A | 0-9.1A | 0-6.7A | 0-4.5A | |
External potentiometer | External potentiometer control (voltage, current) | |||||||||
Analog voltage control | 0 – 5V/0 – 10V control (voltage, current) | |||||||||
Auxiliary power supply | 12V 0.5A | |||||||||
Remote control switch | Default power on, high level power off (3V-12V) | |||||||||
Environmental characteristics | Operating temperature | -20-+60℃ | ||||||||
Operating humidity | -20-90%RH without condensation | |||||||||
Storage temperature/humidity | -40-+85℃,10-95%RH without condensation | |||||||||
Vibration resistance | 10-500Hz, 2G 10 minutes/cycle, 60 minutes for each of X, Y and Z axes | |||||||||
Safety and electromagnetic compatibility | Insulation resistance | Input to output: 100Mhms/500VDC/25℃/70%RH | ||||||||
Pressure resistance | I/P-0/P:1.2KVAC I/P-FG:1.2KVAC 0/P-FG:0.5KVAC | |||||||||
Product size | 277*155*70mm(L*W*H) | |||||||||
Net weight | 2.6 KG | |||||||||
Remark | 1. All parameters are measured at 230VAC input voltage, rated load and 25℃ unless otherwise specified. | |||||||||
2. Ripple and noise voltage are measured with a 20MHz bandwidth oscilloscope with 0.1μ and 47μ capacitors added to the end of a 12-inch twisted pair, and measured at 20MHZ bandwidth. | ||||||||||
3. Accuracy: includes setting error, linear regulation rate and load regulation rate. | ||||||||||
4. Output must be derated in low input voltage conditions, please refer to the static characteristic curve for details. | ||||||||||
5. Startup time is measured under cold start, and frequent switching may increase the startup time.” |