• SE-2000
  • SE-2000

SE-2000

Description:

SE-2000 is a 2KW single output enclosure AC to DC/DC to DC power supply.
The entire series has an input voltage range of 90-132VAC/180-264VAC (selectable by switch)/254-370VDC, and can provide DC output to meet most industrial needs.
Each model can be cooled by an internal speed-controlled fan and the operating temperature can reach 70℃.
Built-in functions such as adjustable output voltage and current, remote on/off control, auxiliary power supply and other functions provide a variety of design flexibility

Inquiry >

  • Type and Specification
ModelSE-2000-24SE-2000-36SE-2000-48SE-2000-70SE-2000-110SE-2000-220
OutputDC output voltage24V36V48V70V110V220V
CharacteristicsRated current83.3A55.5A41.6A28.6A18.2A9.1A

Current range0-83.3A0-55.5A0-41.6A0-28.6A0-18.2A0-9.1A

Rated Power1999.2W1998W1996.8W2002W2002W2002W

Ripple &Noise(Max)200mVp-p300mVp-p300mVp-p500mVp-p600mVp-p800mVp-p

Voltage adjustment range0-24V0-36V0-48V0-70V0-110V0-220V

Voltage accuracy±1%±1%±1%±1%±1%±1%

Line Regulation±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%

Load Regulation±1%±0.5%±0.5%±0.5%±0.5%±0.5%

Startup &Rise Time1500mS,30mS/230VAC

Keep Time30mS/230VAC(Fully loaded)
InputInput voltage180-264VAC/245-370VDC
Frequency range45-65HZ
Power FactorPF≥0.65/230VAC(Fully loaded)
efficiency86%87%89%90%90%91%
AC Current<20A
Leakage Current<3.0mA/240VAC
ProtectShort CircuitEnter constant current
Over temperatureShut down the output,automatically recover or restart after the temperature drops
FunctionOutput voltage adjustment0-26.4V0-39.6V0-52.8V0-79.2V0-121V0-242V
Output constant current0-83.3A0-55.5A0-41.6A0-27.7A0-18.1A0-9A
adjustment
External potentiometerExternal potentiometer control(voltage,current)
Analog voltage control0-5V/0-10V control(voltage,current)
Auxiliary power supply12V0.5A
Remote control switchDefault power on,high level power off (3V-12V)
EnvironmentalOperating temperature-20-+60℃
Operating humidity-20-90%RH without condensation
Storage temperature-40-+85℃,10-95%RH without condensation
and humidity
Vibration resistance10-500Hz,2G10 minutes/cycle,60 minutes for each ofX,YandZ axes
SafetyInsulation resistanceInput to output:100Mhms/500VDC/25℃/70%RH
Pressure resistanceI/P-O/P:1.2KVACI/P-FG:1.2KVACO/P-FG:0.5KVAC
OtherSize277*155*70mm(L*W*H)
Net weight2.6KG
Remark1.All parameters are measured at 230VAC input voltage,rated load and 25℃ unless otherwise specified.
2.Ripple and noise voltage are measured with a 20MHz bandwidth oscilloscope with 0.1μand47μcapacitors
added to the end of a 12-inch twisted pair,and measured at 20MHZ bandwidth.
3.Accuracy:includes setting error,linear regulation rate and load regulation rate.
4.Output must be derated for low input voltage conditions,please refer to the static characteristic curve for details.
5.Startup time is measured under cold start,and frequent switching may increase the startup time.


Get a quote

SE-2000

Prev:SE-1500

Next:SE-3000

Contact Us
We will answer you 24 hours a day
+86 15858810718